•Purge Saver Energy Management System - Shuts Off
•Regeneration Cycle when Limit Temperatures are Reached
•iSTE Exclusive Logic Pro Information Center
System Inlet and Regeneration Temperature Readouts
•Pre and After-Filters Installed
•Filter Drains
•Filter Differential Pressure Indication
•Premium Electronic Switching Valve
•Tuned Regeneration System (Patent Pending)
•Industrial Duty Blower
•Low-Watt Incoloy Heater
•Heater Over-Temperature Protection with Alarm
•Dew Point Sight Glass
•Tower Stainless Steel Bezel Pressure Gauges
•ASME/CRN Pressure Vessel (iSTE-100 and Larger)
•Purge Exhaust Muffler
•Full Charge of USA Desiccant
• Pre and After-Filters Installed
• Filter Drains
• Pre-Filter Differential Pressure Indication
• Diaphragm Directional Valves
• Tuned Regeneration System (Patent Pending)
• High Volume Blower
• Low-Watt Incoloy Heater
• Dew Point Sight Glass
• Tower Pressure Gauges
• ASME/CRN Pressure Vessels (iSTUE-100 & Larger)
• Purge Exhaust Muffler
• Full Charge of USA Desiccant
Optional Equipment
• Three (3) Valve System Bypass
• Dual Filter Packages
• High Pressure (to 800 PSIG)
• Tower Insulation
• Outdoor Insulation
ALLEN BRADLEY PLC CONTROLLER
• 4 line digital display
• NEMA 4X enclosure
• Selectable cycles
• UL listed Components, CSA, CE approved
E-Z SWITCHING VALVES
• Three way valve reduces number of valves
• Soft switching for extreme valve life
• L.E.D. valve position indicator
• Three Year Switching Valve Warranty
FACTORY INSTALLED FILTERS
• Hard point mounting for installation integrity
• Delta PSI gauges for element condition
• Filter drains
REGULATED PURGE (HL 100 & Larger)
• Easy to set
• Optimum purge regardless of operating pressure
• Repressurization Circuit
DEWPOINT INDICATORS ON EACH TANK
• Operator can tell at a glance condition of dew point
• CSA compliant
• PLC digital controller (UL Listed) by Allen Bradley
• Selectable operation for dew point requirements
• NEMA 4X control panel enclosure
• Adjustable purge
• OSHA approved mufflers
• 1000 PSIG non-lubricated inlet valve
• Stainless steel liquid filled gauges
• Stainless steel CRN approved safety valves
• Stainless steel needle control valve (NW 15-40)
• Stainless steel control tubing and 316 ss compression fittings
• Schedule 80, A106B piping, 3000# A105 fittings
• Swage bushings and hex plugs
• Touch Pad Interactive Display Screen
• ASME/CRN code pressure vessels
• Logic Pro Advanced Control System
• Field adjustable operating parameters
• System Run/Standby Selector switch
• Emergency stop button and alarm
• Premium Inlet Switching Valves with 3 year warranty
• Separate High and Low Voltage Control Boxes with Single Point
Power Connections
• Tri-temp Heater Control System
• Heater Protection Over-Temperature Shut Down with Alarm
• Low Watt Density Heaters
• Exhaust Temperature Monitors
• Tuned Regeneration Temperature Control with dual contactors
• Industrial Duty Blower (iDBPE Only)
• Control Air Regulating Valve with Gauge and Orifice Union
• Control Air Filter (Required Only on iDHPE/iDBPE-1000 and Larger)
• -400F Pressure Dew Point Standard
• Adjustable/Selectable 2% Stripping Cycle (iDBP Only)
• Heatless Back-Up Mode
• Re-Pressurization Circuit
• Low Temperature Alarm
• Touch Pad Interactive Display Screen
• ASME/CRN code pressure vessels
• Logic Pro Advanced Control System
• Field adjustable operating parameters
• System Run/Standby Selector switch
• Emergency stop button and alarm
• Premium Inlet Switching Valves with 3 year warranty
• Separate High and Low Voltage Control Boxes with Single Point
Power Connections
• Tri-temp Heater Control System
• Heater Protection Over-Temperature Shut Down with Alarm
• Low Watt Density Heaters
• Exhaust Temperature Monitors
• Tuned Regeneration Temperature Control with dual contactors
• Industrial Duty Blower (iDBPE Only)
• Control Air Regulating Valve with Gauge and Orifice Union
• Control Air Filter (Required Only on iDHPE/iDBPE-1000 and Larger)